三菱GPS-III详细故障代码说明
来源:本站 发布时间:2014-02-21 17:30:49 点击次
MON1=1
MON0=0:
7SEG1=1:INV温度检测;
=2:E-STOP次
=3:CC-WDT三次
=4:SLCWDT三次
=5:电机过电流
=6:制动器电阻过载
=7:接触器故障
=8:终端减速开关故障
=9:平层开关故障
=A:称量装置故障
=B:E1板故障
=C:UHS/DHS开关故障
=D:DZ检测回路故障
=E\F:无
MON0=1:
7SEG1=1:远程复位检测;
=2:选层器错误16次
=3:串行故障
=4:电容器容量不足
=5:手动运行按钮故障
=6:速度图形跳转5次
=7:#LB接触器动作失败5次
=8:#5接触器动作失败5次
=9:#BK1接触器动作失败5次
=A:#BK2接触器动作失败5次
=B:LVLT5次
=C:E1板故障
=D:风扇故障
=E\F:风扇或E1板故障
MON0=2:
7SEG1=1:#5 ON故障;
=2:E-STOP两次
=3:系统故障
=4:再复位请求
=5:PCB基极驱动故障
=6:DC-CT故障
=7:无
=8:浸水感应器故障
=9:反浸水动作结束
=A:#PWD开关指令持续三分钟
=B:扶手开关保持
=C:制动器拖动运行结束
=D:制动器再动作故障
=E:无
=F:选层器故障运行16次
MON0=3:
7SEG1=1:MELD过载;
=2:异常低速
=3:异常高速
=4:反转定时
=5:反向运行
=6:反转定时器(CWT)
=7:反转定时器(CWT BS标准)
=8:逆变器过电压
=9:逆变器欠电压
=A:CC-WDT四次
=B:SLC-WDT 4次
=C:逆变器过电流
=D:SLC E-STOP
=E:编码器故障(自动)
=F:编码器故障(手动)
MON0=4:
7SEG1=1:两次E-STOP;
=2:INV欠电压
=3:E-STOP F/F复位
=4:#LB线圈故障
=5:#5线圈故障
=6:#BK1线圈故障
=7:#BK2线圈故障
=8:上电
=9:无
=A:无
=B:逆变器充电失败
=C\D\E\F:无
MON0=5:
7SEG1=1:电气安全回路
=2:#29锁存
=3:断电
=4:INV欠电压
=5:12V电源故障
=6:控制屏打开
=7:手动过载运行
=8:驱动S/W E-STOP
=9:管理S/W E-STOP
=A:无
=B:异常制动器滑动距离
=C\D\E\F:无
MON0=6:
7SEG1=1:逆变器欠压;
=2:PCB基极驱动故障
=3:INV保护回路动作
=4:#29锁存
=5:12V电源故障
=6:温度开关超75度
=7:温度开关超90度
=8:温度开关冷却/接插件断线
=9:逆变器过电流
=A:逆变器过电压
=B:断电(DC电源故障)
=C:E1板警告
=D:DC电源故障
=E:AC电源故障
=F:#PWD(电源故障检出)
MON0=7:
7SEG1=1:CC-WDT 5次;
=2:CC-WDT 4次
=3:CC-WDT 3次
=4:SLC-WDT 5次
=5:SLC-WDT 4次
=6:SLC-WDT 3次
=7\8\9\A\B:无
=C:称量印板低于30度
=D:称量印板低于30-40度
=E:称量印板超过60度
=F:称量装置A/D转换
MON0=8:
7SEG
下一篇:电梯上行超速保护有那些方式